MEGGER TPT420 DIGITAL & LED 2 POLE VOLTAGE & CONTINUITY TESTERWITH OPTIONAL MEGGER PROTECTIVE CASE AND CALIBRATION IF REQUIRED
12 MONTHS MEGGER WARRANTY
TESTER, CASE & CALIBRATION OPTIONS - PLEASE READ BEFORE PLACING YOUR ORDER
You can purchase using the following options from the drop down menus at the top of this listing.
TPT420 Tester only.
TPT420 With a Megger Case designed for the tester.
There is also the option to purchase our calibration service for either of the above two options.
If you just require the Megger case without the tester then there is also an option to do so - this case will also fit ALL previous versions of the Megger 2 pole tester range TPT210, TPT220,TPT320
MEGGER TPT420 DESCRIPTION
The Megger TPT420 voltage tester is designed to provide
electricians and electrical engineers with an easy to use
voltage indicating instrument. The meter will continue to
warn the operator of dangerous test voltages even when
the batteries are exhausted.
With both LCD and LED displays, the TPT420 provides both
AC and DC voltage measurement - from 12 to 1000 V AC
and up to 1500 V DC. In addition, a continuity function
within the range 0 to 500 kΩ, is included and for added
safety, continuity and voltage measurements are also
accompanied by an acoustic sounder.
A bright, integrated LED torch aids the operator when
working in poorly lit environments.
When testing between
phase and earth on any circuit protected by an RCD,
RCBO and Safety Breaker, the TPT420 is designed to work
below the tripping threshold of these devices to help avoid
unintentional disconnection.
The phase rotation indication test has been simplified,
which now avoids the crossing of the test probes, adopted
by some 2 pole testers. The TPT420 can also perform a
single pole voltage indication test.
With safety in mind, the TPT420 is rated at CAT IV 1000 V with an IP64 housing and conforms to the latest IEC/EN 61243-3 and din VDE 0682-401 standards. For compliance, GS38 probe tip shrouds are provided as standard.
APPLICATION
Although designed for testing within electrical installations, the unit can be used in almost any application where voltage and continuity measurements are required, including automotive, fire alarm & solar/PV systems.
TESTER, CASE & CALIBRATION OPTIONS
You can purchase using the following options:
TPT420 Tester only.
TPT420 With a Megger Case designed for the tester.
There is also the option to purchase our calibration service for either of the above two options.
If you just require the Megger case without the tester then there is also an option to do so - this case will also fit ALL previous versions of the Megger 2 pole tester range TPT210, TPT220,TPT320
Megger TPT420Specifications:
Display
13 LEDs, 4 Digit LCD (0.1V Resolution)
Voltage range
LED: ±12, 24, 50, 120, 230, 400, 690, 1000 V
LCD: 12 - 1000 V AC/1500 V DC
Voltage Warning Indication LED
<50 VAC, <120 VDC
Backlight
Automatic
Polarity indication
Automatic
Frequency range
40 – 400Hz
Peak current
Single pole test
100 – 1000 V AC (50/60 Hz)
Phase Rotation
120 - 400 V Phase to phase, AC 50/60 Hz
Continuity Indication
>500 kΩ + 50%
Overvoltage category
CAT IV 1000V
Pollution Degree
2
Protection
IP64
In compliance with
EN 61010, EN 61243-3:2014, din VDE 0682-401
Operating Temperature
-5 to 40°C (Storage:-20 to 70°C)
Humidity
Max 85% RH
Altitude
Up to 2000 m
Power supply
2 x 1.5V batteries. Type AAA LR03
Length of cable
Approximately 1.2m
Dimensions
Approximately 255 (H) x 67 (W) x 30mm (D)
Weight
Approximately 207g
-
Same Day Despatch if Ordered Before 2pm Mon-Fri
We provide a VAT receipt with EVERY purchase
FREE Delivery to ALL UK Destinations & E
xpress options available at checkout.
We also offer:
Weekend Courier Delivery Service
Please contact us for further details.
12 MONTHS MEGGER WARRANTY TPT420 Tester only. MEGGER TPT420 DESCRIPTION APPLICATION TESTER, CASE & CALIBRATION OPTIONS TPT420 Tester only. Megger TPT420Specifications: Display Voltage range LCD: 12 - 1000 V AC/1500 V DC Voltage Warning Indication LED <50 VAC, <120 VDC Backlight Automatic Polarity indication Automatic Frequency range 40 – 400Hz Peak current Single pole test 100 – 1000 V AC (50/60 Hz) Phase Rotation Continuity Indication >500 kΩ + 50% Overvoltage category CAT IV 1000V Pollution Degree 2 Protection IP64 In compliance with Operating Temperature -5 to 40°C (Storage:-20 to 70°C) Humidity Max 85% RH Altitude Up to 2000 m Power supply 2 x 1.5V batteries. Type AAA LR03 Length of cable Approximately 1.2m Dimensions Weight Approximately 207g - We also offer: Weekend Courier D